Intensification factor
i |
Max. outlet flow
l/min |
Max. inlet flow
l/min |
|
1.0
|
28.1
|
30.0
|
| 1.2 | 24.5 | 30.0 |
| 1.5 | 21.9 | 35.0 |
| 2.0 | 17.0 | 35.0 |
| 3.0 | 13.1 | 40.0 |
| 3.9 | 8.7 | 40.0 |
| 5.2 | 8.4 | 45.0 |
| 7.1 | 6.2 | 45.0 |
| 10.1 | 4.4 | 45.0 |

The basic operation is illustrated in the function diagram. Media 1 is fed through the IN port flowing freely through the bistable valve BV1 driving the LP pistons. From the suction inlet IN Media 2 is drawn through the check valves 2 x KV1, and pumped through the 2 x KV2 to the high-pressure side H. In this condition maximum flow trough the booster is achieved giving a fast forward function.
The unit will automatically stall when end pressure on high-pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the HP1 and HP2 units will automatically operate to maintain the end pressure.
Function Diagram

| Connection | IN / R | H1, S1, H2 & S2 | D1 &D2 |
| 1 | 1/2" BSP | 1/2" BSP | 1/8" BSP |
| IN / R | H | |
| 1/2" BSP | 1/2" BSP | |
| with steel washer | 13.0 da/Nm | 13.0 da/Nm |
| with aluminium washer | 7.0 da/Nm | |
| with cutting edge | 13.0 da/Nm | 13.0 da/Nm |
Media 1: Recognized hydraulic fluids, glycol solutions (Min > 5%)
Media 2: Hydraulic fluids, glycol
Please note! For other media, such as methanol,
please contact miniBOOSTER
• Body & internal components: Stainless steel 316 W.1.4404
• Dynamic seals, H-pur (other seal systems available)
Ordering example of a HC6D2W with i = 3.9,